DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1765TIE-TRK (Analog Tie Trunk)
9
1018 ABORT The test has been disabled via administration.
Verify that the 'Maintenance T est ' field on the 'Trunk Group' form is set to 'n.’ To
enable the test, issue the 'change trunk-group x' command (x equals the
number of the trunk group to be tested). Then, change the entry in the
'Maintenance Test' field on the form to 'y.'
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not alloc ate the necessary system reso urces to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7, FAIL The conference capabilities of the port failed (Error Code 7).
129, The reflective 404-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 129).
131, or The reflective 1004-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 131).
133 The reflective 2804-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems are
suspected (see notes on the next page).
1. To make sure the problem is on-board, disconnect the port from the CO
and retry the test. Coordinate this with the CO, or do it after busy hours;
otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, d isable the test. If
the retry passes and troubles have been reported, refer the problem to the
CO.
More information continues on the next page.
Table 9-661. TEST #33 Looparound and Conference
Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page