Maintenance Object Repair Procedures
9-631DS1-BD (DS1 Interface Circuit Pack)
9
The
list measurements ds1 summary
command will disp lay the length of time the
test ran (
Test Duration
field) and number of b it errors detected (
Loopback/Span Test Bit-Error Count
field).
To restore the trunks or ports on the TN767E DS1 Interface circuit pack to the
in-service state, execute the relea se board command.
Table 9-253. TEST #1216 End Loopback/Span Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the
test ds1-loop UUCSS end-loopback/span -test
command at
1-minute intervals a maximum of 5 times.
1005 ABORT End Loopback/Span Test cannot be executed in the c urrent configuration. To
run this, the TN767E or later suffix DS1 must be admin istered for 24-channel
operation. The "Bit Rate" fiel d on the DS1 circuit pack administration form must
be set to "1.544" for 24-channel operation.
1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or ports of
the DS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
ABORT Internal system error
2100 ABORT Could not allocate the necessary system re sources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page