DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-16ADX8D-PT (AUDIX Digital Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy por t or link. This is an off-board problem
that is detected b y the port circuit. If th is problem exists, replac e the
circuit pack (see caution at the beginning of this section). Once the
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the
voice port. When an error with the link is detec ted, an on-board co unter is
incremented. Also see Note (a).
c. This is an internal type error that occ urs when an audit request fails.
d. The port is busied-out by command. You can release the port via the
release port UUCSSpp command.
Table 9-6. DEFINITY AUDIX Digital Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UU CSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to
20 None WARNING OFF
15(c) Any None
18(d) 0 b usyout port
UUCSSpp WARNING OFF release port UUCSSpp
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port UUCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13) MIN/WRN2
2. Minor alarms on thi s MO ma y b e downgraded to Warning alarms based on the va lue s us ed in the
set options command.
ON test port UUCSSpp l r 3
2049 NPE Crosstalk T est
(#9) MIN/WRN2ON test port UUCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None