DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-697DTMR-PT (Dual Tone Multi-Frequency Recei ver Port)

9
Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time slot information and sanity audit is performed on the DTMR port.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT Could not allocate the nec essary system resources to run this test
1. Retry the command at one-minute intervals a maximum of five times.
2006 ABORT DTMF detection failed. Make sure that the companding mode administered for
the system matches that of the Tone Detector: mu-law for TN748, A-law for
TN420.
1-3 FAIL DTMF digits were not correctly detected.
1. Run the Short Test Sequence: test port UUCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced . In order to restore the system performance to
normal, replace the Tone Detector c ircuit pack c ontaining the defec tive
DTMR port.
PASS The DTMR port is able to detect all the touch-tone dig its.
Table 9-271. TEST #43 Tone Detector Audit/Update Test
Error
Code Test
Result Description/ Recommendation
None ABORT The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute and try aga in.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT C o uld not allocate the nec essary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-270. TEST #42 Tone Detection Verification Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page