DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1251PKT-INT (Packet Interface Circuit Pack)
9
For the case where not all links are in the ‘‘Failed Links’’ category, examine
the alarm log and error log f or failures of the following circuit p ack types
and follow the repair proc edures for those circuit p acks before
considering rep lacing the associated Packet Interface circ uit pack:
Expansion Interface circuit p ack (EXP-INTF)
Switch Node Interface circ uit pack (SNI-BD)
Switch Node Clock circuit p ack (SNC-BD)
Packet Data Line circuit pac ks and ports (PDATA-BD, PDATA-PT)
ISDN-BRI Line circuit packs, ports, an d stations (BRI-BD,
BRI-PORT, BRI-SET)
Packet Gateway circuit pac ks and ports (PGATE-BD, PGATE-PT)
Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
Error Log Entries and Test to Clear Values
Table 9-497. Packet Interface Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
010 Any Any ON test packet-interface CS l r
2
1 (a) Any None MAJOR2ON reset packet-interface CS3
10 (b) 0 None
23 (c) 0 None MAJOR2OFF
23 (d) 0 None MINOR OFF
50 (e) 0 None
100 (f) 0 None
150 (g) 0 None MAJOR ON test packet-interface CN l c
200 (h) 0 None MAJOR2OFF
217 (j) 0 None WARNI NG OFF
257 (i) Any None MAJOR2ON reset packet-interface CS3
267 (j) 0 None WARNI NG OFF
513 (k) Any None MAJOR2ON reset packet-interface CS3
769 (l) Any Maintenance
Looparound Test
(#886)
MAJOR2ON test packet-interfac e CS s r
2