DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-298BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
9
board and all maintenanc e actions referring to ASAI and Luc ent adjunct Links in
this section apply.
The TN556, TN2198, and TN2208 ISDN-BRI Lines are packet port circuit p acks
that provides acc ess to ISDN-BRI endpoints. The ISDN-BRI Line circuit packs
supports 12 ports , each of which provides access to ISDN stations. Voice and
circuit-switched data from the ISDN stations are carried on the Time Division
Multiplex (TDM) Bus. Signaling is carried over the Packet Bus.
LEDS
The ISDN-BRI Line circuit pack performs ex tensive initialization tests and lights
both the red and g reen LEDS during the initialization testing. See Chapter 7,
‘‘LED Interpretation’’, for more details on circuit p ack status LEDs.
Hardware Error Log Entries and Test to Clear
Valu es
Table 9-136. BRI-BD Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test board UUCSS sh r 1
1(a) Any None MINOR ON
18(b) 0 b usyout board
UUCSS WARNING OFF release board UUCSS
23(c) 0 None WARNING OFF
257(d) 65535 Control Channel
Loop Test (#52) MINOR ON test board UUCSS r 20
513(e) 4352 to
4357
769(f) 4358
1025(g) 4363 NPE Audit Test
(#50)
1293 to
1294 (h) 46088 to
46096 SAKI Sanity Test
(#534) MINOR ON See footnote (h)
1537
to
1538 (i)
46082 MINOR ON
Continued on next page