9-1132OPS-LINE (DS1 Off Premises Station Line)
9
1018 ABORT The test was disabled via translation.
1. You may want to determine why the test has been disabled before you
enable it.
2. To enable the test for the particular analog station being tested, enter the
’change station extension’ command, and then change the ’Test’ field on
the ’Station’ form from ’n’ to ’y.’
1020 ABORT The test did not run due to an already existing error on the specific port or due
to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error. (Error code 1793
indicates a problem with the DS1 interface board, and any problems on
the associated DS1-BD or UDS1-BD should be resolved first.)
2000 ABORT The test was aborted because response to the test was not received within the
allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 9-450. TEST #7 Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page