DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-89display errors
8
display errors
display errors [high-resolution] [print | schedule]
The display errors c ommand brings up an input form that allows you to selec t
which errors will be disp layed on the hardware error report.
Errors can result from in-line firmware errors, periodic tests, failures d etected
while executing a test comm and, software inconsistency, or a data aud it
discrepancy. The Error Log is restricted in size. A new entry overwrites the oldest
unalarmed entry. The overwritten entry must be at least six minutes o ld, or the
new entry is dropped .
Help Messages
The following help message will b e displayed when the first p age of a multiple
page list of alarms/errors or after the Pre v Page key is pressed:
Press CANCEL to abort or NEXT PAGE for next page
The following help message will b e displayed after the Next Page key is pressed
and there are more pages of alarms/er rors to be displayed:
Press CANCEL to abort, NEXT PAGE for next page, PREV PAGE for
previous page
The following help message will b e displayed after the Next Page key is pressed
and there are no more alarms/errors to be dis played:
Press CANCEL to abort, NEXT PAGE to complete, PREV PAGE for
previous page

Actions

The following command will display the next page of alarms/errors or echo
“Command succ essfully completed” and exit if there a no more pages of
alarms/errors to display:
Next Page
The following command will d isplay the previous pag e of alarms/errors and the
“press CANCEL to abort or NEXT PAGE for next page” help message:
Prev Page
Name Administered name from the data mod ule forms (Processor
Inter face , X.25, Ethern et, an d PPP)