DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-730DUP-CHL (Duplication Interface)
9
12. If the SPE Stand by Sta te-of -Heal th is f unct ional as ob serve d wit h the
status spe command, use the reset system interchange command. With
the other SPE now active, execute the busyout spe-standby command
and use the test duplication-interface long clear command to test the
Duplication Channel in the other d irection, resolving any outstand ing
alarms against DUPINT and DUP-CHL.
If these tests pass, continue with step 13.
13. Execute the release spe-standby command and wait for memory
shadowing and stand by refreshed to comp lete as verified with the status
spe command.
If the standby is not refreshed within 10 minutes, c ontinue with step
14.
If the standby is refreshed within 10 minut es, this replacement
procedure is succ essfully finished.
14. Use the status spe command. If the status shows MAJOR alarms, use the
display alarms command with the spe category selection. Resolve
alarms for maintenance objec ts other than DUPINT and DUP-CHL.
If the standby is not refreshed within 10 minutes, or the DUPINT and
DUP-CHL alarms are not resolved, escalate the prob lem.
If the standby is refreshed within 10 minutes, and the DUPINT and
DUP-CHL alarms are resolved, this replacement p rocedure is
successfully finished .