1418 ABORT The HFAIL bit being set in the active Duplication Interface circuit pack
prevented this test from running.
1. Run this long demand test sequence and verify that test #870 passes or
follow the repair strategy for test #870 until it passes.
2000 ABORT This test did not run because communication with the standby timed out while
waiting for a reply to a maintenance message.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
2334 ABORT The hardware mailbox in the standby Duplication Interface circuit p ack is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The expected interrupt was not received from the standby Duplication
Interface circuit pack when the FIFO was filled to overflowing with test data.
1. Replace Duplication Interface components starting with the standby
Dupl icatio n Interf ace ci rcuit p ack. U se SPE Dupl icatio n Channe l
Component Replacement procedures at the end of this DUP-CHL section.
53 FAIL The Duplication Interface circ uit pack FIFO flow control flag was not set during
this FIFO Full Interrupt Test.
1. Replace Duplication Interface components starting with the standby
Dupl icatio n Interf ace ci rcuit p ack. U se SPE Dupl icatio n Channe l
Component Replacement procedures at the end of this DUP-CHL section.
54 FAIL The attempt to turn on memory shadowing in this DUPINT circuit pack could
not be verified in the DUPINT hardware status register.
1. Replace Duplication Interface components starting with the standby
Dupl icatio n Interf ace ci rcuit p ack. U se SPE Dupl icatio n Channe l
Component Replacement procedures at the end of this DUP-CHL section.
PASS The FIFO full interrupt was received from the standby Duplication Interface
circuit pack when the FIFO was filled to overflowing with test data.
Table 9-274. TEST #871 FIFO Full Interrupt Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page