Maintenance Object Repair Procedures
9-36ADX16A-PT (AUDIX Analog Line/Control Link)
9
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is in use, it is unavailable for certain tests.
Wait until the port is idle before testing.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1001 ABORT Could not allocate the necessary system resources to run this test.1
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS er rors and is not handling heavy traffic, then
retry the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is in use, it is unavailable for certain tests.
Wait until the port is idle before testing.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1005 ABORT This condition indicates that the test is not applicable when the analog p ort
is used in a combined modem pool. This error can be ignored .
1018 ABORT Test disabled via administration.
1. To enable the test for the particular analog station being tested, enter
the change station
extension
command and change the Test? field
on the Station Form to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2012 ABORT System could not respond to this request.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-13. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page