DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-52change fiber-link
8
Output
The following fields appear on Page 2 when a DS1 CONV complex is
administered on the fiber link. O nly the DS1 CONV complex
attributes
are
administered here. The circuit p ack itself is administered by change circuit
pack. Entries on Page 2 represent the A-PNC. If the PNC is duplicated, these
fields are repeated on Page 3 for the B- PNC. Page 3 fields are display-only, and
can be chang ed only by chang ing their counterp oints on Page 2.
Fiber Link # This display-only field shows the id entifying number of the fib er link
entered on the command l ine.
Board
Location The physical addres s (cabinet-carrier-s lot) of the circuit pac ks
comprising the two end points (ENDPOINT-1 and ENDPOINT-2) of the
fiber link.
Board Type This display-only field shows the typ e of circuit p ack administered at
each endpoint (“ ei” or “sni”).
DS1
Converter? y indicates that a DS1C Converter Complex is us ed on this link to
remotely locate a port network. If this is th e case, a second p age
displays for administra tion of the DS1C Complex attributes.
Board
Location This field under the heading DS1C-1 is used to define the physical
location of the converter board connected to ENDPOINT-1. It is a
data entry field consisting of the board’s p hysical address b y
cabinet-carrier-slot. When the loc ation is entered, validation is
performed to ensure that the b oard has been administere d and is of
the correct type (DS1 CONV).
DS1 Converter
Facilities The fields under this heading define attributes of the four DS1
facilities (A, B, C, D) that can be c onnected to the DS1 CONV.
Facility
Installed? This specifies (y or n) whether the indicated fac ility has been
provided and installed. Facility A is required for the DS1 CONV
Complex.
Passes
Far-end
Clock?
This specifies whether the DS1 CONV can use the timing of the
received signal as a c lock source (as when p assing timing from a
master PN to a slave PN. If the DS1 signal does not come direc tly
from the far-end DS1 CONV board or the network, n should be
entered. (For example, when using a ‘c ombined’ facility in which the
signal is converted from digital to analog and back to digital.)
Digital Data
Compatible? This specifies whether the facility is suitab le for transmission of dig ital
data. Facility A must be so and this field cannot be c hanged. If
Customer Premises Equipment that alters digital data exists on this
facility (for example, a channel exp ansion multiplexer or a comb ined
DS1 facility), n should be entered . (Thus, a multiplexer cannot b e
installed on facility A).