DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-60ANL-24-L (24-Port Analog Line)
9
ANL-24-L (24-Port Analog Line)
The 24-Port Analog Line circuit pac k (TN793) provides 24 ports for voic e
terminals and supp orts both on-premises and off-p remises analog voice
terminals.
No maintenance of the terminal connec ted to the 24-Port Neon Analog Line
circuit pack is performed, excep t to determine whether or not the terminal is
connected. Failures of the neon messag e waiting lamp power and the common
ringing app lication circuitry are rep orted as part of common p ort circuit pac k
errors. See errors 1281 and 1793 in the “XXX-BD (Common Port Circuit Pack)”
section.
NOTE:
This analog line circuit p ack supports analog data modules. When
assigned, analog d ata modules provide ac cess to the Net Pkt (TN794) data
ports. To activate an analog data mod ule you must assign the port location
on the data form and c onnect a modem to the port. (The analog data
module may be used for c onnection to a CDR output or other adjun cts as
needed.) These ports are tested the same as all other analog ports on the
circuit pack.

Ringing Caused by Maintenance Testing

Test #48 may cause some terminal equipment to ring briefly during d aily
maintenance. If this ringing is disturbing the c ustomer or the terminal equipment,
it should be disab led in the Test? field of the change station extension form. Be
aware that this action also disabl es Tests #6, 7, 161, and 35.
MO Name (in
Alarm Log) Alarm Level Initial Command to
Run1
1. UU is the universal cabine t number (1 for PPN, 2 -44 for EPNs); C is the carrier
designation (A, B, C, D, or E); SS is the number of the slot in which the c ircuit pack res ides
(01 to 21); and pp is the two digit port number (01, 02, ...).
Full Name of MO
ANL-24-L MIN test port UUCSSpp l 24-Port Analog Line
ANL-24-L WRN test port UUCSSpp sh 24-Port Analog Line