8-119format card-mem
8
Examples
enable test-number 102
This command will re-enable a sp ecified test that was previously turned off with
the disable test command. (The disable test comman d is not available to the
craft login.) While disabled a test cannot be run b y background or demand
maintenance. Before enabling a te st, ascertain why it was disab led, and inform
INADS that it has been turned bac k on.
Parameters
format card-mem
This command formats the active and standby proc essor Flash Read-Only
Memory.
Synopsis
format card-mem [translati on] [announcements] [coredump ]
Permissions
The following default logins may exec ute this command: b rowse, system
technician, cust, inad s, init.
Examples
format card-mem translation
format card-mem announcements
format card-mem coredump
Description
The maintenance command, “for mat card-mem translation” will erase and format
the memory card for translations only. The maintenance c ommand format
card-mem announcement will erase and format the memory c ard for
translations and announcements. The maintenanc e command format card-mem
coredump will erase and format the memory c ard for translations,
announcements and cored ump.
test# The number of the test to be re-enabled
Descriptions of each tes t appear under the relevant MO in Chapter 9. See the
Index for a numerical list of all d emand maintenance tests.