Table 9-382. TEST #306 EPN Maintenance Circuit Pack
Reset Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of 5 times.
1018 ABORT Test disabled via software patch.
2029 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
2500 ABORT Internal system error.
1. Retry the command at one-minute intervals a maximum of 5 times.
1204 FAIL
1205 EI circuit pack could not reset the EPN Maintenance circuit pack. For
duplicated Port Network Connectivity:
1. The standby EI circuit pack may be defec tive and, thereby, preventing the
active EI circuit pack from resetting the EPN Maintenance circuit pack.
Unplug the standby EI circuit pack, and attemp t to reset the EPN
Maintenance circuit pack using the test maint long command. If Test #306
passes, replace the standby EI circuit pack, and attempt the reset test
again. If Test #306 fails, then replace the Standby EPN EI circuit pack.
2. The active EI circuit pack may be defective and unable to reset the EPN
Maintenance circuit pack. Interchange the PNC by entering the reset pnc
interchange command. Now reset the EPN Maintenance circuit pack again
by using the test maintenance long command. If the test passes, the
problem is with the known standby EI circuit pack. Repeat Step 2 to
determine if the standby EI circuit pack should be replaced.
Continued on next page