DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-632DS1-BD (DS1 Interface Circuit Pack)
9
2000 ABORT Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of servic e and one or more of
the following symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the p orts are
properly installed .
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of the trunks for this circuit pack are placed into the out of
service state. The system will try to restore the circuit pack within 15
minutes. When no faults are detected for 15 minutes, the DS1 interface
circuit pack is restored to normal operation. All of the trunks for the DS1
interface circuit pack are then returned to the in service state.
Hyperactivity is often caused by the associated facility. In such a case,
faults (such as slips, misframes, or blue alarms) would be entered in the
error log. In addition, many hardware errors would be logged against
the associated trunk circuits. If the facility is OK and the error occurs
again after 15 minutes, replace the circuit pack.
1313 FAIL The TN767E DS1 circuit pack could not deactivate the loopback through the
Customer Loopback Jack.
1. Retry the
test ds1-loop UUCSS end-loopback/span -test
command at
1-minute intervals for a maximum of 5 times.
1314 FAIL The TN767E DS1 circuit pack could not deactivate the loopback through the
far-end CSU.
1. Make sure that the far-end DS1 is installed if the far-end CSU is a 120A
CSU Module.
2. Retry the
test ds1-loop UUCSS end-loopback/span -test
command at
1-minute intervals for a maximum of 5 times.
PASS The active long-duration loopback or span test on the TN767E circuit pack
was successfully terminated.
Table 9-253. TEST #1216 End Loopback/Span Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page