DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-761EPN-SNTY (EPN Sanity Audit)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error 8801 occurs whenever the EPN is unable to send up -link control
messages and the control c hannel of the TDM Bus in the EPN has been
switched as part of the recovery proced ure.
b. Error 8803 occurs each time whenever the EPN is unable to send up-link
control messages and the EPN Tone-Clock has been switched as part of
the recovery proced ure.
c. Error 9901 occurs whenever the EPN is unable to send up-link control
messages, but recovers after the c ontrol channels of the TDM Bus in the
EPN are switched.
d. Error 9902 occurs whenever the EPN is unable to send u p-link control
messages, but recovers after the ac tive Tone-Clock in the EPN is
switched.
e. Error 9903 occurs whenever the EPN is unable to send up -link control
messages, but recovers after a PNC interc hange has taken place.
f. Error 9904 occurs whenever the EPN is unable to send up -link control
messages, but recovers after an EPN WARM reset.
g. Error 9905 occurs whenever the EPN is unable to send u p-link control
messages, but recovers after an EPN COLD reset.
Table 9-294. EPN-SNTY Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any None
8801 (a) Any None
8803 (b) Any None
9901 (c) Any None
9902 (d) Any None
9903 (e) Any None
9904 (f) Any None
9905 (g) Any None