DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-767ETH-PT (Control LAN Ethernet)

9
TCP/IP PING Test (#1281)

This non-destructive test fails if all the end points fail to respond. Use this test to

check the circuitr y in the data path for a peer-to-p eer IP layer connection.

System software launches a ping on a maximum of 3 end points reachab le on this

port. The test fails if all of the pings fail. The tes passes if even 1 of the pings i s

successful.

Table 9-297. TEST #1278 Ether Local Looparound Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT The port is in use.
1. Determine status of port (status clan-port UUCSSpp).
2. If port is idle, retry the Looparound Test (#1278).
3. If port is not idle, busyout the circuit p ack (busyout port UUCSSpp).
2000 ABORT Did not receive c ircuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout port UUCSSpp
and reset board UUCSS).
2. If the problem persists, replace the circ uit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100 ABORT Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
1 FAIL Circuit pack detected failure in the Ethernet Local Looparound Test (#1278).
1. If the problem persists, reset the circuit pack (busyout port UUCSSpp
and reset board UUCSS).
2. If the problem persists, replace the circ uit pack.
PASS The circuitry tests properly.
Continued on next page