DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-448CO-TRK (Analog CO Trunk)
9
2012 ABORT An internal software error occurred.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2053 ABORT The test call could not be established, but no information on why is
available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2056 ABORT An error occurred while trying to obtain results from the TN771 circuit pack.
1. Test the TN771 circuit packs.
FAIL Measured transmission performance was in the unacceptable rang e as
administered on the trunk group form. Retrieve a measurement report via
the list testcalls command. Make sure that ATMS thresholds are set
properly on page 4 of the trunk group form. Besides the facility, test failures
can be caused by faulty test lines or switch paths. If the measurements
point to a facility problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk is
usable but has an undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report via the list testcalls co mmand. Make sure
that ATMS thresholds are set properly on page 4 of the trunk group form.
Table 9-186. TEST #844-848 Transmission Test — Continued
Error
Code Test
Result Description/ Recommendation