Maintenance Object Repair Procedures
9-154ATM-BCH (ATM B-Channel Trunk)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate problems in the order presented in the tab le below. When you
clear one of the error codes asso ciated with a given test, you c lear errors
generated by other tests in t he testing sequence. If you c lear errors out of order,
you can lose important infor mation.
Signaling Link State Audit Test (#255)
This non-destructive test chec ks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 9-64. System Technician-Demanded Tests: ATM-BCH
Order of Investigation Short Test
Sequence Long Test
Sequence Destructive or
Non-destructive
Signaling Link State Check Test (#255) X X ND
Service State Audit Test (#256) X X ND
Call State Audit Test (#257) X X ND
ISDN Test Call Test (#258) X ND
Continued on next page
Table 9-65. TEST #255 Signaling Link State Audit Test
Error
Code Test
Result Description/ Recommendation
None ABORT Internal system error
0 ABORT
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018 ABORT Maintenance disabled
1. Enable maintenance. Enter y in the Maintenance Tests? field on
page 2 of the change trunk-group for m.
Continued on next page