Maintenance Object Repair Procedures
9-1100M/T-ANL (Maintenance/Test Analog Port)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors. i
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 3 times.
1004 ABORT The port was seized by a valid ATMS Test Call.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort and the port is not in use on a valid ATMS Test
Call, escalate the problem. To determine whether the port is in use by an
ATMS Test Call enter status station ext where ext is the assigned ATMS
station number.
2000 ABORT Response to the test re quest was not received within the allowable time period.
1. Retry the command at 1 minute intervals a maximum of 3 times.
7 FAIL Conference test failed on the primary information channel.
1. Run the circuit pack tests to check the Tone/Clock (TONE-BD) circuit pack
and the Tone Detector circuit pack via the test board UUCSS command.
2. Resolve any problems that are detected on the Tone/Clock (TONE-BD)
circuit pack or Tone Detector circuit pack. See the section on Tone
Generator circuit pack.
3. If the Tone/Clock and Tone De tector circuit packs are functioning properly,
and the test still fails, replace the Maintenance/Test circuit pack.
14 FAIL The primary information channel is not transmitting properly. User may not
notice any interruption in service or may not be able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack using test board UUCSS.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack. See the section on Tone Generator
circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Maintenance/Test Circuit Pack.
PASS The Maintenance/Test Analog Port analog trunk testing capability is operating
correctly.
Table 9-437. TEST #13 Analog Port Digital Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page