DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-490DID-TRK (Direct Inward Dial Trunk)
9
Table 9-201. TEST #33 Looparound and Conference Circuit Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Enter display port UUCSSpp to determine the station extension,
attendant number, or trunk group/member number of the port. Use
status station, status attendant, or status trunk to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing. Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
2. If the port stat us is active but the po rt is not in use (no calls), c heck the
Error Log for Error Type 513. The port may be locked up.
3. If the port statu s is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call d uring the test.
1. Enter display port UUCSSpp to determine the station extension,
attendant number, or trunk group/member number of the port. Use
status station, status attendant, or status trunk to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing. Attendants are always in use (off-hook), if the handset is
plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT Test disabled via administration. Verify that the Maintenance Tests?
field on the Trunk Group Form is set to n. To enable the test, issue the
change trunk-group x command (x is the trunk group number). Then
change the entry in the Maintenance Tests? field to y.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT System resources required to run this test are not available. This may be
due to the port being seized.
1. This abort code is usually associated with tone-clock (TONE-BD,
TONE-PT, and TDM-CLK) resources. Clear any tone errors in the error
log.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page