DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1020MAPD-BD (MAPD Interface Circuit Pack TN802)

9
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is hig hly destructive and c an only be initiated by a system tech nician-demanded reset boar d UUCSS command.
FAIL The circuit pack failed to return the circuit pac k code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is one of the Port circuit
packs, replace the circuit pac k.
3. Otherwise, if the circuit pack is part of the SPE, use the procedure
described in
Replacing SPE Circuit Packs
in Chapter 5.
PASS Communication with this circuit pack is successful.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 9-394. TEST #52 Control Channel Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page