DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-535DIOD-TRK (DIOD Trunk)
9
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the status trunk
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT Test has been disabled via administration.
1. The Maintenance Tests? field must be set to y on the trunk group form
for this test to run. This form is accessed with the change trunk-group
grp# command.
1005 ABORT Trunk has been administered as incoming-only; or DID trunk group type; dial
tone can only be obtained on outgoing trunks. This is a normal condition.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of five times.
FAIL Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any errors and repeat
test.
2. If error has still not cleared, refer problem to CO.
2002 FAIL Seizure portion of test failed due to hardware problem. Fault is usually caused
by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test if wiring
correction made.
2. Locate another identical CO trunk and swap its wiring with one under test.
Repeat test on both trunks and determine if problem follows trunk or
remains at original port. If problem follows trunk, refer problem to CO. If
problem remains at port, replace circuit pack and repeat test.
1009 PASS Detected tone was not pure dial tone. No action required.
PASS Trunk was seized, and dial tone was detected. User-reported troubles on this
port should be investigated by using other port tests and b y examining trunk or
external wiring.