DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-534DIOD-TRK (DIOD Trunk)

9
System Technician-Demanded T ests: Descripti ons
and Error Codes

Always investigate tests in the order they are p resented in the table below. By

clearing error cod es associated with the

NPE Crosstalk Test,

for example, you

may also clear errors generated from o ther tests in the testing sequence.

Dia l To ne Te st (# 0)

This test attempts to seize a port and c hecks for the return of a dial tone.

Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
NPE Crosstalk Test (#6) X ND
Dial Tone Test (#0) X ND
Looparound and Conference Test (#33) X ND
Audit Update Test (#36) X X ND
Table 9-219. TEST #0 Dial Tone Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the command display port UUCSSpp to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT Could not allocate the necessary syste m resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page