DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-327test cdr-link
8
The following display shows a typ ical result when test board 1D07 is entered
and slot 1D07 hods a Digital L ine circuit pack with 7 p orts administered.
test cdr-link
The test cdr-link co mmand validates that a call d etail recording link has b een
administered and estab lished.
Parameters
For more information see ‘‘Common Input Parameters’’ and ‘‘Common Output
Field s’’ at the beg inning of this chapter.
test customer-alarm
test customer-alarm UUC [short | long] [repeat # | clear] [schedule]
test cdr-link primary | secondary
[short | long] [repeat number | clear] [schedule]
[primary | secondary] A system may have up to two CDR links: a primary th at is
normally used and a seco ndary that serves as a backup in
case the primary fails. This qualifier specifies which link to test.
Primary is the default.
test board 1d07 short SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01D07 DIG-BD 52 PASS
01D0701 DIG-LINE 5401 16 PASS
01D0701 DIG-LINE 5401 17 PASS
01D0702 PDMODULE 5460 17 PASS
01D0703 PDMODULE 5461 17 ABORT 5
01D0704 PDMODULE 5444 17 ABORT 5
01D0705 DIG-LINE 16 ABORT 1392
01D0705 DIG-LINE 17 ABORT 1392
01D0706 DIG-LINE Attd2 16 PASS
01D0706 DIG-LINE Attd2 17 PASS
01D0707 DIG-LINE Attd1 16 PASS
01D0707 DIG-LINE Attd1 17 PASS
Command Successfully Completed