DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-249ATM-SYNC (ATM Synchronization)
9
ATM-SYNC commands
Use the following command s to help troubleshoot ATM-SYNC problems:
Error Log Entries and Test to Clear Values
change
synchronization Allows primary and secondary referenc es to be
administered for the Stratum 4 option, or ATM-Switch,
indicating that the synchronization references are input
directly to the ATM switch
status
synchronization Shows the current inferred sync hronization reference
status
synchronization Shows the administered p rimary and second ary
synchronization references
list timing-source Displays all DS1 and UDS1 locations that are allowed to
be administered as p rimary or secondary referenc es
with the change synchronization command
disable/enable
synchronization-
switch
Prevents or allows switching to another sync hronization
source
test
synchronization Tests the administered s ynchronization source
Table 9-107. Synchronization Error Log Entries
Error Type Aux
Data Associated
Test Ala rm L ev el On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test synchronization
1 (a) (g) None WARNING/
MINOR OFF None
257 (b) (g) None WARNING/
MINOR OFF None
513 (c) (g) None WARNING/
MAJOR OFF None
1537 (d)2
2. It may take up to 1 hour for these alarms to clear via the “leaky bucket” strategy.
None WARNING OFF None
1793 (e)20-50 None NONE OFF None
2049 (f)20 None WARNING OFF None
Continued on next page