DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1283PMS-LINK (Property Management System Link)
9
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. The PMS Link has been busied out with the busyout pms-link command .
The link is torn down. Enter the release pms-link command to restore the
link.
b. The Link Retry Test (#215) fails. An error was detected when setting up the
link. Refer to the
Procedures for Restoring the PMS Link
above.
c. The PMS physical link is down for one of the following reasons:
Cable to the PMS device is disc onnected.
Table 9-504. PMS Link Maintenance Error Log Entries
Error
Type Aux Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test S equence first. If all tests pass, run the Long Test S equence. Refer to th e appropriate
test description and follow the recommended proc edures.
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-li nk
257 (b) Any Link Retry Test
(#215) MINOR/2
WARNING
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF test pms-link l
513 (c) Any None test pms-link
769 (d) Any None
1025 (e) 40-49 None
1281 (f) 10-19 None
1537 (g) N0-N9 None
1793 (h) Any None test pms-link
2049 (i) Any None
2305 (j) 50-59 None release pms-link or test
pms-link
2561 (k) Any None test pms-link
2817 (l) 100-109
200-209
300-309
None
3073 (m) 70-79 None
3841 (n) 20-29 None