9-1466SNI-BD (SNI Circuit Pack)
9
acti ve SNC a nd th e SPE, an a ttemp t wil l be m ade t o rese t the SN I via its
neighbor.
An SNI should be reset instead of reseating the circuit pac k. The reset board
command should almost nev er be used on an SNI. It may be nec essary to use
the reset board command if the SNI circ uit pack gets into a mod e where it
cannot communicate with so ftware.
If an SNI with active errors and alarms is reset, the errors and alarms may ta ke a
while to come back, therefore the reset board command can mask real
problems.
Table 9-563. TEST #761 Switch Node Interface Reset Test
Error
Code Test
Result Description/ Recommendation
2100 ABORT Could not allocate the nec essary system resources to run th is test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2302 ABORT Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2303 ABORT The SNI circuit pack responded that the software test requested is invalid.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2304 ABORT SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page