DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-32ADX16D-P (16-Port AUDIX Digital Port)
9
7 FAIL Conference Test failed on the primary channel. In some cases, users may not
notice a disruption in service. In extreme cases, the conferencing feature may
not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may range
from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the proc essor and AUDIX is not transmitting
properly. User impact may range from no noticeable effect to loss of use of this
port. This failure could also be disruptive to other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the AUDIX.
1. Run circuit pack tests to check the tone generator circ uit pack and the tone
detector circuit pack using test board UUCSS s.
2. Resolve any problems detected on the tone generator circuit pac k or tone
detector circuit pack.
3. If the tone generator and tone detector circuit p acks are functioning
properly, and if the test still fa ils, replace the AUDIX (see caut ion at the
beginning of this section).
PASS Voice and Control Channel Loc al Loop test passed . All channels are
transmitting prop erly.
1. To be sure that this is not an intermittent problem, repeat this test up to 10
times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 9-11. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page