Maintenance Object Repair Procedures
9-1310PNC-DUP (PNC Duplication)
9
v. A spontaneous PNC interchange took p lace in response to the retiring of
an alarm on the B-PNC associated with fault c lass FC_SNIHW. Use status
pnc to look at the state of health indexes for the PNCs, and investiga te any
associated alarms. The last two dig its of the error code indic ate the
fiber-link number (01-27) of the fib er that reported the retired alar m. List
fiber-link gives the location of the fiber.
w. A spontaneous PNC interchange took p lace in response to the oc currence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
EAL. This indicates that one or more Expansion Archang el Links are down.
Investigate any EXP-PN alarms. Adding 1 to the last two digit s of the error
code gives the PN number of the port network that reported the alarm.
(21003 points to port network 4.) List config port-network g ives the
cabinet number assoc iated with a port network.
x. A spontaneous PNC interchange took p lace in response to the oc currence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
INL. This indicates that one or more neighb or or indirect neighb or links
with an EI as an endpoint have experienc ed faults. Investigate any alarms
agai nst EXP-PN and SN -CON F. Add ing 1 to t he las t two d ig its of the er ror
code gives the PN number of the port network that reported the alarm.
(21103 points to port network 4.) List config port-network g ives the
cabinet number assoc iated with a port network.
y. A spontaneous PNC interchange took p lace in response to the oc currence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
HW. This indicates that one or more neighbor or ind irect neighbor l inks
with an EI as an endpoint have experienc ed faults. Investigate any alarms
agai nst EXP-PN and SN -CON F. Add ing 1 to t he las t two d ig its of the er ror
code gives the PN number of the port network that reported the alarm.
(21203 points to port network 4.) List config port-network g ives the
cabinet number assoc iated with a port network.
z. A spontaneous PNC interchange took p lace in response to the oc currence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
PER. This indicates faults on peer links that connect SNIs to EIs.
Inves tiga te any alarm s aga inst SN I-PEER. Ad din g 1 to the las t two d ig its of
the error code gives the PN numbe r of the port network that reported the
alarm. (21303 points to port network 4.) List config port-network gives
the cabinet number assoc iated with a port network.
aa. A spontaneous PNC interchange took p lace in response to the oc currence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
DS1. This indicates faults on one or more DS1C facilities. Investigate a ny
alarms against DS1-FAC. Adding 1 to the last two d igits of the error code
gives the PN number of the port network th at reported the alarm. (21403
points to port network 4.) List config port-network gives the cab inet
number associated with a p ort network.
ab. A spontaneous PNC interchang e took place in resp onse to the occurrence
of a major or minor alarm on the B-PNC associated with fau lt class FC_
SNIL. This indicates faults on peer or neighb or links between SNIs on