DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1571SYNC (Synchronization)

9
Figure 9-95. Synchronization Troubleshooting, Page 2 of 6
SLIPS
ON DS1
FACILITIES?
No
No
Yes
A
2
4
IS
THIS SWITCH
SUPPOSED TO BE
TIMING MASTER?
FROM
PAGE 1
SLIPS
ON EI’S, SNI’S,
TONE CLOCKS?
DONE
TO
PAGE 5
C
PROBLEM
IS IN
SWITCH
Yes
EXAMINE
SYNCHRONIZATION
PLAN FOR
NETWORK
REFER PROBLEM
FOR INVESTIGATION
AT OTHER END
OF FACILITY
Yes
No
MAKE CHANGES TO
HAVE SWITCH OPERATE
IN ACCORDANCE
WITH NETWORK
SYNCHRONIZATION PLAN