DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-120ANN-PT (Announcement Port)
9
2. Performing a test board long when the circuit p ack is in this state will
yield the following abor t codes:
Ports 1 AND 9 abort Test 206 with code 1024.
Ports 1 AND 9 abort Test 205 with code 2000.
Board level Tests 209 and 210 abort with cod e 1024.
3. The save/restore announcements command will time out with:
Error encountered, can’t complete request
The Announcement circuit pac k lock-up can b e cleared remotely by per forming
a soft reset to the circuit pac k:
busy-out board UUCSS (this command drop s all calls in progress on the
Announcement circuit p ack).
Reset circuit pack using the reset board UUCSS command.
Release board using the release board UUCSS c ommand.