DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1687TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
9
Level 1 Status Inquiry Test (#1242)
This test is nondestructive.
This test determines the state of the transmission facility of a BRI por t at the
Level 1 (L1) physical layer: Ac tivated, Pending Ac tivation, or Deactivated.
The Activated state is the correct stat e for an ISDN-BRI port. In this state the L1
interface can send and receive synchronized signals. This test passes if the state
of L1 is Activated. This test also passes if s oftware has taken this port out of
service. See the descriptio n of the L1 “Deactivated State” b elow for more details.
The Pending Activation state indicat es a problem with the channels, the wiring , or
the TBRI-BD circuit pack. When in this state, the Level 1 inter face is either not
receiving any L1 framing from the c hannel, or it is communicat ing with the
channel but cannot transiti on to the Activated state.
Table 9-634. TEST #625 Receive FIFO Overflow
Error Counter Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack with the busyout board UUCSS and reset board UUCSS
commands.
2. If the test aborts again, replace the circuit p ack.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
value FAIL The TBRI-BD circuit pack is still detecting errors of this type. The Error
Code field contains the value of this counter.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, run the Long Test Sequence and pay
particular attention to the Looparound Tests (#618 and #619). See the
repair procedures for the executed test if it fails. Otherwise, go to the
next step.
3. Replace the circuit pack.
PASS The Receive FIFO Overflow error counter was read correctly and has a
value of 0.
Continued on next page