DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-332test ds1-loop
8
Help Messages
If the system technician presses HELP after entering “ test ds1-loop” the following
message will be displayed:
Enter DS1 board location,
[’cpe-loopback-jack-test-begin [number-of-bits bit-pattern]’ or
’far-csu-loopback-test-begin’ or’one-way-span-test-begin’ or
’end-loopback/span-test’ or’inject-single-bit-error’ or
’ds1/csu-loopback-tests’]
Error Messages
If the format for the board location is incorrect, the following error messag e will
be displayed:
Port/Board invalid
If the EPN in which the specified b oard resides is not availab le, the following
message will be displayed:
EPN is not available
If the specified b oard is not inserted in the system, the fo llowing message will be
displayed:
Board not inserted
If the command entered is in confli ct with another currently executing command,
then a message will be d isplayed showing the log in id of the conflicting user and
the conflicting c ommand. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a c ommand a resource prob lem occurs that requires
the user to restart the command, then the follow ing message will be d isplayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resourc es are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
If the test ds1-loop command is executed and the “G3 Version” field on the
“system-parameters custom er-options” form is not V3 or later, then the following
message will be displayed:
G3 Version must be V3 or later
If the test ds1-loop command is exec uted on a circuit p ack other than TN464F or
TN767E or later DS1 board, then the following message will b e displayed:
Command valid for TN464F or TN767E or
later release DS1 circuit packs