DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1088MODEM-PT (Modem Pool Port)

9
The Modem Pool Conference Test checks most of the switching and gain control functions provided by the NPE circuit in the analog section of the conversion resource. This test conferences a 1004-Hz tone throug h the NPE, looping it back so that it can be verified w ith a Tone Detector circuit
Table 9-432. TEST #97 Modem Pool Conference Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1000 ABORT System resources required to run this test are not available. The port may be in
use on a valid call. Determ ine whether the port is availab le for testing.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum of 5
times.
1004 ABOR T The port has been seized by a user for a valid call. Determine whether the port is
available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit pack,
and attempt to diagnose previously existing errors.
2000 ABORT The response to the test was not received in the allowable time period.
2012 ABORT Internal system error.
2100 ABORT System resources required for this test are not available.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page