DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1776TIME-DAY (Time of Day)
9
TIME-DAY (Time of Day)
The time of day contains the current year, month, d ay of the week, day of the
month, hour, minute, and second . The Time of Day maintenance object is
responsible for monitoring the ti me-of-day clock and rai sing an alarm if the
time-of-day clock is not set or cannot be read by the software. If the time-of-day
clock is not set or cannot be read by the software, many features such as
Time-of-Day Routing, CDR, ISDN Call-by-Call, Duplication, and so on will be
either inoperative or incorrect. The time-of-d ay clock should b e set using the set
time command whenever the system is initially powered up or the TN1648
SYSAM circuit pack is replaced .
The time-of-day clock can b e read with the display time command and set via
the set time command. The time-of-day c lock resides on the TN1648 SYSAM
circuit pack and has a backup b attery to save the time of day during power
failures. If the TN1648 SYSAM circuit pack is physic ally removed from the carrier,
the contents of the time-of-day c lock is lost and the time of day must b e set when
the TN1648 SYSAM circuit pack is re-inserted.
Error Log Entries and Test to Clear Values
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use the display time command to displ ay the time of day. If the time of
day is displayed correctly, wait 15 minutes and verify that the alarm is
retired. If the alarm has not been retired, c ontinue with Step 3.
MO Name (in
Alarm Log) Alarm
Level Initial Command To
Run Full Name of MO
TIME-DAY MINOR set time Time of Day
Table 9-666. Time of Day Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
00Any AnyAnydisplay time
2471
1. This err or i nd ic a tes th at s oft wa re c a nno t re ad th e ti me -of -d ay c loc k o n t he TN 164 8 SYSAM
circuit pac k. During th is c o nd ition, all ti me stam p s on Ala rm Log entries, Hard wa re Error Log
entries, and Software Error Log entries are potentially inaccurate. In addition, any features that
are sensitive to the time of day (suc h as SMDR, Time-of-Day Routing, ISDN Call-by-Call) will not
function correctly.
0 none MINOR OFF set time