DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-675DS1 CONV-BD
9
Error Log Entries and Test to Clear Values
20. reset pnc-interchange Force the system to the B-PNC while you change
hardware, cables, and administration.
21. status pnc Verify that the B-PNC is active.
22. Go back to Step #2 Use Steps #2 through 18, this time for the B-PNC.
Table 9-262. DS1 CONV Board Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test board UUCSS sh r 1
1(a) Failure Audit Test
#949 MAJOR ON/OFF test b oard UUCSS sh r 1
18(b) 0 busyout board
UCSS WNG OFF release board UCSS
125(c) 3 None MINOR ON
218(d) any None MAJOR ON
257(e) Failure Audit Test
#949 MINOR ON test board UUCSS sh r 1
513(f) 1 Failure Audit Test
#949 MAJOR ON test board UUCSS sh r 1
513(g) 2 Failure Audit Test
#949 MAJOR ON test board UUCSS sh r 1
513(h) 3 Failure Audit Test
#949 MAJOR ON test board UUCSS sh r 1
513(i) 4 Failure Audit Test
#949 MAJOR ON test board UUCSS sh r 1
513(j) 5 Failure Audit Test
#949 MAJOR ON test board UUCSS sh r 1
769(k) 1 Failure Audit Test
#949 MINOR ON/OFF test board UUCSS sh r 1
769(l) 2 Failure Audit Test
#949 MINOR ON/OFF test board UUCSS sh r 1
Continued on next page
Table 9-261. Convert from DS1-CONV to direct-connect fiber in a duplicated PNC — Continued
√# Command/Step Description
Continued on next page