9-1155PDATA-PT (Packet Data Line Port)
9
Table 9-458. TEST #558 LAPD Connectivity Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT The port is in use for a call. Use status data-module extension command to
determine when the port is available for testing.
1. Retry the command when the port is idle. The port may be forced to the
idle state by executing busyout port UUCSSpp. This command is
destructive caus ing all calls and links assoc iated with the port to b e torn
down.
1137 ABORT The test link could not be created.
1. If the PDATA port is in an EPN, this is probably caused by Center Stage
maintenance interactions. The Center Stage includes the Switch Node
Interface (SNI), Expansion Interface (EI) and DS1C boards. Clear any
problems in these boards before continuing.
2. Retry at one minute intervals for a maximum of 3 times.
1139 ABORT The Packet Bus in this port network is out-of-service.
1. Retire the alarm associated with the Packet Bus. Please refer to the
maintenance section on the packet bus for details.
2. Retry the command when the alarm associated with the Packet Bus is
retired.
1141 ABORT The Packet Interface, PKTINT, Circuit Pack (TN1655) is out-of-service.
1. Refer to the repair procedures for the PKTINT circuit pack to put the circuit
pack back into service.
2. Retry the command when the alarm associated with the Packet Interface is
retired.
1144 ABORT The Packet Bus in the Port Processor Network (Network 1) is alarmed.
1. Retire the alarm associated with the Packet Bus in the Port Processor
Network. Please refer to the maintenance section on the packet bus for
details.
2. Retry the command when the alarm associated with the Packet Bus is
retired.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals for a maximum of 3 times.
Continued on next page