DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-61ANL-24-L (24-Port Analog Line)

9
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time. Aux Data 40960 indicates that too many sim ultaneous incoming ring ing attempts were made on this board . Only 4 ports on a board may ring simultaneously. A 5th incoming call will c ause an inline error from the board.Aux Data 40975 indicates that the terminal equipment was on-hook when ring-tip was detec ted during ring ing. This usually indicates a failure in the terminal equipment or the typ e of terminal has a low ringer imp edance.
Table 9-26. 24-Port Analog Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test (#36)
18 0 busy-out station
extension
WRN ON release station

<extension>

130(c) None WRN ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station Present
Test (#48) WRN OFF test port UUCSSpp sh r 2
769 Battery Feed Test
(#35) MIN/
WRN2
2. Minor alarms on this MO may be down graded to Warning alar ms based on the values used in the set
options command.
ON test port UUCSSpp sh r 2
1025 Looparound Test
(#161) MIN/
WRN2ON test port UUCSSpp l r 2
1281 Conference Test
(#7) MIN/
WRN2ON test port UUCSSpp l r 2
1537 NPE Crosstalk Test
(#6) MIN/
WRN2ON test port UUCSSpp l r 2
Continued on next page