DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-430CO-TRK (Analog CO Trunk)
9
Notes:
a. These are in-line errors that have no specific test as sociated with them.
Refer to the following table for an explanation a nd appropriate action.
b. This is a software audit error that does not ind icate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that t he circuit pack ha s been removed or has
been insane for at least 11-minutes. To clear the error, reinsert or replac e
the circuit pac k.
d. Aux data 57345 Single pola rity ringing current
Aux data 57376 No loop current on incoming call
Aux data 57408 No tip ground detected on outgoing call
1793 Looparound and
Conference Test
(#33
MAJ/MIN/
WRN2ON test port
UUCSSpp
l r 3
2049 NPE C ross Ta lk Test
(#6) MAJ/MIN/
WRN2ON test port
UUCSSpp
l r 3
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
2817 (d) 57484 Dial Tone Test(#0) MAJ/MIN/
WRN OFF test port
UUCSSpp
l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone Test(#0) MAJ/MIN/
WRN OFF test port
UUCSSpp
l r 1
3585 (d) 57424 None
3840 (f) 8000 Transmission Tests
(ATMS)(#844-848) OFF test analog-testcall
3841 (f) Transmission Tests
(ATMS)(#844-848) MINOR OFF test analog-testcall
1. Run the Short Test S equence first. If all tests pass, run the Long Test S equence. Refer to the appropriate
test description and follow the recommended proc edures.
2. Major alarms may be downg raded to Warning alarms bas ed on the value used in the set option s
command.
Table 9-179. CO Trunk Error Log Entries — Continued
Error
Type Aux Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page