DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-84ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
1018 ABORT Test disabled via administration. The default for the Test? field on the is
y; thus, you may want to determine why this field has been set to “n” on
this station (this may be due to the ringing application Test E48, which can
be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the Test? field to y.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the disp lay shows a t for the port).
2. If either list config or display port indicate that the port is
not
a TTI
port, escalate the problem. If both commands indicate that the port is
a TTI port, the abort is correct for the test, and no action is necessary.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a
system allocation to get information about the port or to pu t the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock p roblem). The tone-clock and
tone detectors could be having a communic ation problem, for example,
the companding modes could be out of sy nchronization.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The port’s battery feed chip is unable to sup ply sufficient power to the
terminal equipment. This may occur when the test is performed at the
same time that the terminal equipment goes off-hook.
1. Use status station to determine when the port is available for testing.
When the port becomes available for testing, retry the command at
1-minute intervals a minimum of five times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the circuit pack only if the
customer is experienc ing problems.
Table 9-34. TEST #35 Battery Feed Test Results — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page