DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-290AUX-TRK (Auxiliary Trunk)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Ty pe 1 with Aux Data 57481 indicates a port fault. Use an empty port
if one is available until the circ uit pack can b e replaced.
b. Error Type 1 or 769 with Aux Data 57482 indicates a fault on sig naling
lead, which is an off-board error. This error should only occur with
loudspeaker pag ing. If the trunk is being used for another applic ation,
check that the administration i s correct. Otherwise, chec k the wiring to the
external equipment co nnected to the Auxiliary Trunk and chec k the
external equipment.
c. This is a software audit error that does not ind icate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
d. Indicates the c ircuit pack has b een removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit p ack.
Table 9-131. Auxiliary Trunk Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 57481 None
1(b) 57782
15(c) Any Audit Up d ate Test (#36)
18 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
130(d) None WARNING ON test trunk <grp> /<mbr> sh
769(b) 57482 None
257 Hybrid/Conference MIN/WRN2
2. Major or Minor alarms may be downgraded to Warning alarms based on the values used in the set
options command.
ON test p ort UUCSSpp l r 3
Circuit Test (#33)
513 NPE Crosstalk Test (#6) MIN/WRN2ON test port UUCSSpp l r 3
1025 Diagnostic Test
Auxiliary Trunk Test
(#114)
WARNING ON test port UUCSSpp sh r 3