9-295AUX-TRK (Auxiliary Trunk)

9
Trunk state, idle/active/unavailable
Companding mode (A-law or mu-law) [G3r V2
Diagnostic TestAuxiliary Trunk Test (#114)

The system software sends a message to the on-boa rd microprocessor to

operate a relay in the port c ircuit. If ground is d etected, the test passes.

Table 9-134. TEST #36 Audit Update Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1006 ABORT Port is in out-of-service state as a result of being busied out. This audit
cannot be run.
1. Retry the command once the port is in service (Release port UUCSSpp
command has been run).
2100 ABORT Could not allocate the necessary system resources to run this test.
FAIL Internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS This test passed. Translation informat ion was successfully up dated on the
circuit pack.
Continued on next page