DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-820EXP-INTF (Expansion Interface Circuit Pack)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out of service.
1. Enter display errors and follow associated repair procedures for TTR-LEV.
Even if there are no TTR-LEV errors, there may not be a Tone Detector
available on the network that contains the circuit pack being tested. Verify
that there is at least one Tone Detector on this network. If there is not at
least one Tone Detector, this test always aborts for this EI board. This will
not harm the system.
2. Enter display errors and follow associated repair procedures for TONE-PT.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 3 times.
1015 ABORT The system will not allow this test to be run because the EI circuit pack has not
been busied out.
1. Busyout the Expansion Interface circuit pack. Then, repeat the test board
UUCSS long command.
1031 ABORT If the Expansion Interface circuit pack is in an EPN and is on the active PNC,
and is not part of an EPN to EPN link, this test
cannot
be executed. If the
lightwave transceiver looparound is activated, it is impossible to deactivate it.
1. If PNC Duplication is enabled, attempt to make the Standby PNC active
through the reset pnc interchange command.
2. If the PNC Interchange is successful, the lightwave transceiver looparound
test may now be executed on the original Expansion Interface circuit pack.
1033 ABORT The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test.
1. Issue the list fiber-link command to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack (but should be), ad d the
correct fiber using the add fiber-link command.
3. Retry the command.
1139 ABORT The packet bus in the EPN where this EI board is located has a major alarm
against it. This test needs to use the alarmed PN’s packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1141 ABORT The Packet Interface circuit pack is out of service.
1. Refer to ‘‘PKT-INT (Packet Interface Circuit Pack)’’.
Table 9-312. TEST #242 Expansion Interface Lightwave Transceiver Looparound — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page