DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-125ASAI-BD (Multi-Application Platform Board)
9
messages per 10 second s. The switch issues an alarm when the
limit reaches 400; when it reaches 500 up -link messages in 10
seconds, the board is taken out of service.
LED use: the LED Control Message 038x requests the Angel to
drive the red, yellow, and green LEDs on the fac e plate of a typical
port board on or off. On the MAPD, only the red LED is controlled by
this message. Yellow and green change req uests received from the
switch by the MAPD drive LCD b ehavior rather than LED behavior.
The DEFINITY switch continues to send the same LED control
messages to the MAPD that the DEFINITY switch currently sends to
all other port boards. The MAPD handles p roper interpretation of
these messages. You should note that the PC on the MAPD and the
switch itself control the LEDs and the LCD on the MAPD.
Port Administration: in Administration Without Hardware (AWOH),
the switch allows administration o f up to 8 ports in any of the first 12
ports. If the port type later reported by the board does not match
the existing type, the switch a ssumes it to be a MAPD board with a
different configuration and rejects the board.
NOTE:
Refer to the LAN-BD documentation for circ uit pack level
errors. For related information, see ASAI-PT and ASAI-EPT
maintenance documentati on.