DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1875UDS1-BD (UDS1 Interface Circuit Pack)
9
Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a UDS1 Interfac e circuit
pack are in error. The Misframe Alarm Inquir y Test queries the total number of
misframes that have occurred o n a DS1 Interface circuit pack since the last
inquiry.
When the DS1 Interface circuit pac k detects a misframe error, it will increase its
misframe counter by 1. If the c ounter reaches a specified threshol d (i.e.- 17), a
MISFRAME-COUNT message is automatically sent to the switch maintenance
software. After the maintenance software receives the MISFRAME-COUNT
message, the Misframe Alarm Inquir y Test is initiated to collect the misframe
counts from the UDS1 Interface circuit p ack.
When the threshold of misframes is reached, if the UDS1 Interface c ircuit pack is
supplying the system sync hronization source, then a switching s ynchronization
source message is sent to the TDM Bus Cloc k. See TDM-BUS (TDM Bus)
Maintenance documentatio n for details. A Minor alarm against the UDS1
Interface circuit p ack is raised, but all trunks or p orts of the UDS1 Interface
circuit pack remain in the in-service state.
PASS No Slip alarm is detec ted on the UDS1 Interface circ uit pack.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be due
to incorrect translations, no board is inserted, an incorrect board is inserted, or
an insane board is insert e d.
1. Ensure that the board translations are correct. Execute the add ds1 UUCSS
command to administer the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 9-693. TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page