DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Additional Maintenance Procedures
6-47Automatic Transmission Measurement System (ATMS)
6
Input Parameters - List Testcall CommandATMS Summary Reports
The ATMS Summary Report summarizes, on a trunk group basis, the collective
results of the latest ATMS tests performed on each trunk group . By interacting
with the trunk group form, it hig hlights out-of-tolerance measurements. Marg inal
trunks are highlighted, and unusable trunks blink, allowing you to quickly identify
out-of-tolerance or unusable trunks. Screen 6-2 shows a typical summary rep ort.
detail This qualifier specifies a d etailed report that shows eac h measurement
made for each trunk.
summary This qualifier specifies a rep ort that shows totaled results of ATMS tests
for trunk groups as a whole.
grp # This qualifier spec ifies a report showing measu rements for a specific
trunk group. When used with to-g rp, this option specif ies the starting
trunk group in a range .
to-grp This qualifier specifies a report showing measurements for all trunk
groups from 1 up to the trun k group number entered . When used with
grp, this is the ending trunk group in a range.
mem Used with
grp, this qualifier specifies a rep ort showing measurements for
a specific trunk g roup member. When used with to-mem, this is starti ng
trunk group member in a range.
to-mem Used with grp, this qualifier sp ecifies display of measure ments for all
trunk group members from 1 up to the specified trunk group member
entered. When used with mem, this is the end ing trunk group memb er in
a range.
port This qualifier specifies d isplay of measurements for the trunk assigned to
a specific p ort circuit.
result Only measurements that match the spec ified result are disp layed. Result
IDs include pass, marg, fail, and numerical abort cod es.
not-result Only measurement results that do not match the sp ecified result are
displayed.
count number This qualifier limits the total number of rec ords displayed.
print With this qualifier, the command executes immediately (if resourc es are
available) and sends out put both to the screen and to a printer
connected to the termina l where the command was entered.
schedule With this qualifier, a sc heduling form is disp layed which allows you to
specify a start time for the c ommand. The command is plac ed in the
queue and, when executed , sends the output to the system p rinter.