Maintenance Object Repair Procedures
9-26ADX16D-P (16-Port AUDIX Digital Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy por t or link. This is an off-board problem
that is detected b y the port circuit. If th is problem exists, replac e the
circuit pack (see caution at the beginning of this section). Once the
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the
voice port. When an error with the link is detec ted, an on-board co unter is
incremented. Also see Note a, ab ove.
c. This is an internal type error that occ urs when an audit request fails.
Table 9-9. DEFINITY AUDIX Digital Port Error Log Entries
Error
Type Aux
Data Associated
Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to 20 None WARNING OFF
15(c) Any None
18(d) 0 busyout port
UUCSSpp WARNING O FF relea se po rt UUCSSp p
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port UUCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice and
Control Local
Loop TEST
(#13)
MIN/ WRN2
2. Minor alarms may be downgrad ed to Warning alarms base d on the values used in th e set options
command.
ON test port UUCSSpp l r 3
2049 NPE Crosstalk
Test (#9) MIN/ WRN2ON test p ort UUCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None