DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-442CO-TRK (Analog CO Trunk)
9
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status trunk command to
determine the servic e state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times..
1018 ABORT The test was disabled via administration. Verify that the ’Maintenance Test’
field on the ’Trunk Group’ form is set to ’n’. To enable the test, issue the
’change trunk-group x’ command (x equals the number of the trunk group to
be tested). Then, change the entry in the ’Maintenance Test’ field on the
form to ’y’.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
7 FAIL The conference capab ilities of the port failed (Error Code 7).
129 The reflective 404-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 129).
131 The reflective 1004-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 131).
133 The reflective 2804-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems are
suspected (see no t es on the next page).
1. To make sure the problem is on-board, disconnect the port from the CO
and retry the test. Coordinate this with the CO, or do it after busy hours;
otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the test.
If the retry passes and troubles have been reported, refer the problem
to the CO.
Table 9-184. TEST #33 Looparound and Conference
Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page